Algeos

Physioworx Int

Issue link: http://algeo.uberflip.com/i/105354

Contents of this Issue

Navigation

Page 5 of 27

6 ELECTRICAL THERAPY CH2 ON/OFF & Amplitude Control CH2 ON/OFF & Amplitude Control CH1 Output Receptacle CH1 ON/OFF & Amplitude Control CH1 ON/OFF & Amplitude Control CH2 Output Receptacle LDC Panel CH1 Output Receptacle CH1 ON/OFF & Amplitude Control Key Control (Mode, Time, Width, Rate) SET - ENT Control Panel (Key Controls) Slide Cover Slide Cover Physioworx E-Pulse 300 TENS Physioworx E-Pulse 300 EMS Channel: Dual, isolated between channels Pulse Intensity: Adjustable0-80mApeakinto500Ωloadeach channel, constant current. Pulse Rate: 1Hz-160Hz (adjustable), 1Hz/step (1-20Hz), 5Hz/step (20-160Hz) Pulse Width: 50μs - 260μs (adjustable), 10μs/step. Patient Compliance Meter: Shows the treatment times in hours. Patient Lock System: Prevent the user from changing any fixed parameters set by the physician or licensed practitioner. Timer: 15, 30, 60 minute and continuous mode selectable. LCD: Shows modes, pulse rate, pulse width, timer, CH1/CH2. Weight: 140 grams (battery included). Channel: Dual, isolated between channels Pulse Amplitude: Adjustable0-80mApeakinto500Ωloadeachchannel, constant current Pulse Rate: 1Hz-160Hz (adjustable), 1Hz/step (1-20Hz), 5Hz/step (20160Hz) Pulse Width: a. 50-260μs Adjustable for TENS, 10μs/step. b. 250μs Fixed for EMS. Software Ramp Up feature: By changing mode, the output will reset to zero then ramp up to its original setting intensity. It will protect users from a sudden surge. Patient Compliance Counter: Shows the treatment times in hours. Patient Lock System: Prevents the user from changing any fixed parameters set by the physician or licensed practitioner. Timer: 15, 30, 60 minute and continuous mode selectable. LCD: TENS - Show modes, pulse rate, pulse width, timer and CH1/CH2 on LCD panel. EMS - Show modes, pulse rate, on time, off time, timer and CH1/CH2 on LCD panel. PX0333 (L)108mm x (W)61.5mm x (H)25mm PX0360 CH1 ON/OFF & Amplitude control CH2 ON/OFF & Amplitude control CH1 Output receptacle Physioworx E-Pulse 300 with 5 Modes CH2 Output receptacle Key Control (Mode, Time, Width, Rate) LCD Panel Slide cover (L)95mm x (W)61.5mm x (H)26mm Channel: Dual, isolated between channels Pulse Amplitude: Adjustable0-80mApeakinto500Ωloadeach channel, constant current Pulse Rate: 1Hz-160Hz (adjustable), 1Hz/step (1-20Hz), 5Hz/step (20-160Hz) Pulse Width: 50-260μs Adjustable for TENS, 10μs/step. Software Ramp Up feature: By changing mode, the output will reset to zero then ramp up to its original setting intensity. It will protect users from a sudden surge. Patient Compliance Counter: Shows the treatment times in hours. Patient Lock System: By changing mode, the output will reset to zero then ramp up to its original setting intensity. It will protect users from a sudden surge. Timer: 15, 30, 60 minute and continuous mode selectable. LCD: TENS - Shows modes, pulse rate, pulse width, timer CH1/CH2 PX0350 (L)108mm x (W)61.5mm x (H)25mm

Articles in this issue

Links on this page

view archives of Algeos - Physioworx Int